Home > Socket Error > Winsock Bind Error 10014

Winsock Bind Error 10014

Contents

Berkeley description: The quota system ran out of table entries. This is a common problem. A system call that should never fail has failed. This would occur if WinSock aborts an established connection after data retransmission fails (receiver never acknowledges data sent on a datastream socket). http://isusaa.org/socket-error/winsock-error-10049-bind.php

An invalid QoS filter style was used. A couple functions that the v1.1 specification missed are WSASetLastError() and WSAUnhookBlockingHook(). WSAECONNREFUSED 10061 Connection refused. Berkeley description: A component of a path name exceeded 255 (MAXNAMELEN) characters, or an entire path name exceeded 1023 (MAXPATHLEN-1) characters.

Socket Error 10054

WSA_QOS_EFLOWDESC 11026 Invalid QoS flow descriptor. Note that this error is returned by the operating system, so the error number may change in future releases of Windows. An application attempts to use an event object, but the specified handle is not valid.

  1. Of the two that can fail, neither of them set an error value you can retrieve from WSAGetLastError() (refer to Chapter 10, "Support Routines" for more information on any of these
  2. This is usually caused by one or more of the function pointers being NULL.
  3. C/C++ Winsock.
  4. Is MinGW innocent?
  5. Berkeley description: An attempt was made to access an open file (on an NFS filesystem) which is now unavailable as referenced by the file descriptor.
  6. Powered by Blogger. Блоги программистов и сисадминов Winsock Bind Error 10014 - C++ CyberForum.ru - форум программистов и сисадминов > Форум Форум программистов > Форум C++ > Форум C++ и сети
  7. The WinSock implementation was unable to allocate additional memory to accommodate the function request.

Among other things, that is exactly what we've done here. No such host is known. This normally results from an attempt to bind to an address that is not valid for the local computer. Socket Error 10049 Specifically, these error-less functions are the byte order functions ( htonl(), htons(), ntohl(), and ntohs()), the address manipulation functions (inet_addr(), and inet_ntoa), WSAGetLastError() and WSAIsBlocking().

The requested address is not valid in its context. What Is A Socket Error Let do WinSock inspection to understand why WinXP causes that strange side effect. WinSock functions: Additional functions: If a WinSock implementation has an upper limit to the number of simultaneous tasks it can handle, an application's initial call to WSAStartup() could fail with why not try these out LVL 1 Overall: Level 1 Message Author Comment by:F-J-K ID: 229094612008-11-07 Yes listening: TCP [::]:4432 [::]:0

Especially in trivial code. Socket Error 10054 Connection Reset By Peer The requested service provider could not be loaded or initialized. No, no, no. WSAEISCONN 10056 Socket is already connected.

What Is A Socket Error

WinSock description: Similar to Berkeley. Is the router up and running (check by pinging it, and then ping an address on the other side of it)? Socket Error 10054 WinSock description: Partly the same as Berkeley. Socket Error 10053 Why?

This usually means the local software knows no route to reach the remote host. his comment is here Developer suggestions: Did you close a socket inadvertently in one part of an application without keeping another part notified? These conditions are more likely to be indicated by the error WSAETIMEDOUT. Generically, the error means the network system has run out of socket handles. Socket Error 10038

Wait // for more connections by calling accept again on ListeningSocket // and start sending or receiving data on NewConnection. If you wish to continue this conversation start a new topic. TheArchMage 4-Aug-12 23:07pm I'm an idiot. this contact form You can try to fill sin_zero field with non-zero values just to observe how sendto() clears it back as a side-effect (at WinXP).

Networking activity on the local host has not been initiated. Socket Error Codes Linux WinSock functions: bind(), connect(), sendto(), socket(), FD_CONNECT See also: WSAEPROTOTYPE WSAEALREADY (10037) Operation already in progress. WinSock description: Same as Berkeley.

Berkeley description: This is a temporary condition and later calls to the same routine may complete normally (also known as EAGAIN error in Berkeley Software Distribution version 4.3) WinSock description: Same

How does modular arithmetic work - Fermat's last theorem near misses? However, it is interchangeable in most cases, and all Windows Sockets functions that return one of these messages also specify WSAEAFNOSUPPORT. See also: WSAECONNABORTED, WSAENETRESET, WSAETIMEDOUT WSAEDESTADDRREQ (10039) Destination address required. Socket Error 11004 This message has a slightly different meaning from WSAEAFNOSUPPORT.

In it's place, WinSock uses the error WSAENETUNREACH, exclusively. A retry at some time later may be successful. after failed calls to inet_addr() or gethostbyname()), then simply test your address value for zero before you pass it to sendto(). navigate here They signal unusual error conditions for which there's no WinSock error equivalent.

success Windows XP: IPv6... The server application might need to call htons() to translate the port to network byte order in the sockaddr structure. And here is the price. By calling shutdown a partial close of a socket is requested, which is a signal that sending or receiving, or both have been discontinued.