Home > Socket Error > Winsock Connect Error: System Error: 10051

Winsock Connect Error: System Error: 10051

Contents

Under MS-DOS versions 3.0 and later, EACCES may also indicate a locking or sharing violation. It is also possible that WinSock might return this error after an application calls connect() a second time on a non-blocking socket while the connection is pending (i.e. A request to send or receive data was disallowed because the socket is not connected and (when sending on a datagram socket using sendto) no address was supplied. Networking activity on the local host has not been initiated. http://isusaa.org/socket-error/winsock-error-10051.php

This could be due to an out of memory error or to an internal QoS provider error. WSAECONNRESET (10054) Connection reset by peer A connection was forcibly closed by a peer. Developer suggestion: are you trying to use an optional feature? Since the buffering requirements for sending are less than for receiving datagrams, it's conceivable that you can send a datagram larger than you can receive. http://forums.dameware.com/viewtopic.php?f=9&t=245

Socket Error 10038

WSAEADDRINUSE 10048 Address already in use. Why would Snape set his office password to 'Dumbledore'? TCP/IP scenario: In BSD-compatible implementations, the local network system generates this error if there isn't a default route configured. Is the router up and running? (You can check by pinging it, and then ping an address on the other side of it.) Try a traceroute to the destination address to

That they are not trying to use more than one Windows Sockets implementation simultaneously. Of the two that can fail, neither of them set an error value you can retrieve from WSAGetLastError() (refer to Chapter 10, "Support Routines" for more information on any of these WinSock description: The 'address' it refers to is the remote socket name (protocol, port and address). Socket Error 10053 WinSock description: No equivalent.

Winsock description: Winsock doesn't support the sendmsg() function, and some Winsock implementations are not so strict as to require an application with a datagram socket to 'disconnect'--by calling connect with a Socket Error Codes Linux If you used a hostname, did it resolve to the correct address? User suggestions: Do you have the WinSock DLL that supports the version of the WinSock specification required by the application? An invalid value was given for one of the arguments to a function.

Returned by WSARecv and WSARecvFrom to indicate that the remote party has initiated a graceful shutdown sequence. Socket Error 10049 On the server end, you could use a network system utility similar to BSD's "netstat -a" command to check that your server is running, and listening on the right port number. However, there are some TCP/IP dialers that install their own Winsock.dll which may not be compatible with our programs. The occurrence of an unlisted error can provide extra detail.

Socket Error Codes Linux

This normally results from an attempt to bind to an address that is not valid for the local computer. Ping the remote host you were connected to. Socket Error 10038 For inet_addr(), this could mean the content of the buffer passed or the buffer itself is invalid. Socket Error 10054 Connection Reset By Peer WSA_QOS_EPROVSPECBUF 11018 Invalid QoS provider buffer.

WinSock functions: socket() See also: WSAESOCKTNOSUPPORT WSAEPROTOTYPE (10041) Protocol wrong type for socket. his comment is here Berkeley description: A socket operation encountered a dead network. The ICMP message means that the router can't forward the IP datagram, possibly because it didn't get a response to the ARP request (which might mean the destination host is down).WSAENOTEMPTY WinSock functions: recv(), recvfrom(), send(), sendto(), FD_CLOSE Additional functions: Any function that does I/O on the network could generate this error. Socket Error 11004

This error occurs when the sin_port value is zero in a sockaddr_in structure for connect or sendto. DameWare Mini Remote Control - Error - Aurora-M02 : Body Text : Host: [Aurora-M02] 1.) Winsock Connect Error: System Error: type System Message: A connection attempt failed because the connected party An invalid or inconsistent flowspec was found in the QoS provider-specific buffer. this contact form This usually results from trying to connect to a service that is inactive on the foreign host—that is, one with no server application running.

The file's permission setting does not allow the specified access. How To Fix Socket Error This error is returned if an incorrect protocol is explicitly requested in the socket call, or if an address of the wrong family is used for a socket, for example, in after the first failed with WSAEWOULDBLOCK).

WinSock functions: Any function that takes a socket as an input parameter: accept(), bind(), closesocket(), connect(), getpeername(), getsockname(), getsockopt(), ioctl socket(), listen(), recv(), recvfrom(), select(), send(), sendto(), setsockopt(), shutdown(), FD_CONNECT Additional

  1. TCP/IP scenario: A connection will timeout if the local system doesn't receive an (ACK)nowledgement for data sent.
  2. The attempted operation is not supported for the type of object referenced.
  3. You cannot mix and match. (WINSOCK DLLs must be supplied by the same vendor that provided your underlying protocol stack).You cannot use more than one Winsock implementation simultaneously.If you have more
  4. Too many open sockets.
  5. By calling shutdown, you do a partial close of a socket, which means you have discontinued sending.
  6. send() or sendto(): out of buffer space, so try again later or wait until FD_WRITE notification (WSAAsyncSelect()) or select() writefds is set.
  7. Berkeley description: A protocol was specified that does not support the semantics of the socket type requested.
  8. I've made a new VS2010 using MULTI-BYTE for testing and the connect() method returns no error, and ...

For example, you shouldn't necessarily expect to be able to use NS addresses with ARPA Internet protocols. WSAEADDRNOTAVAIL (10049) Can't assign requested address Normally results from an attempt to create a socket with an address not on this machine. WinSock functions: the list of functions that explicitly list this error in the v1.1 Windows Sockets specification. Winsock Error 10054 Fix The ICMP message means that a router cannot forward the IP datagram, possibly because it did not get a response to an ARP request (which might mean the destination host is

The specified socket parameter refers to a file, not a socket. If you are using a host table exclusively, you'll need to update it to add the destination hostname and address. This is not a temporary error. navigate here WorF Новый участник Сообщения: 36 Благодарности: 0 Профиль | Отправить PM | Цитировать В общем такая суть: dwnt запускается из рабочей группы, получаю ремот контроль к доменным компам, но вот не

It’s the normal error message format utilized by Microsoft Windows and other Microsoft Windows compatible applications and driver manufacturers. You can not post a blank message. User suggestions: Check your WinSock, protocol stack, network driver and network interface card configuration. WinSock description: The Windows Sockets definition of this error is very different from Berkeley.

Try to ping this address. –kotlomoy May 30 '13 at 15:18 I tried pinging, and there is no problem. User suggestions: Did you enter a destination hostname? WSATYPE_NOT_FOUND 10109 Class type not found. A retry at some time later may be successful.

In some cases these errors are platform dependent. For example, the error can occur when an attempt is made to read from a file that is not open, to open an existing read-only file for writing, or to open However, some WinSocks fail with WSAEINVAL you call connect. Note that the v1.1 WinSock specification does not explicitly state that this error occurs if the value you request is larger than the WSAData.iMaxUdpDg returned from WSAStartup().

Each implementation may have a maximum number of socket handles available, either globally, per process, or per thread. But i will check it out and see if i can figure out where the problem is. All of the standard Windows NT/2000/2003 Server and Windows NT/2000/XP Workstation utilities are included, along with many DameWare NT Utilities custom NT tools including Mini Remote Control and Exporter.