Home > Winsock Error > Winsock Error 10048 Connect

Winsock Error 10048 Connect

Contents

By calling shutdown a partial close of a socket is requested, which is a signal that sending or receiving, or both have been discontinued. Such exclusive access is a new feature of Windows NT 4.0 with SP4 and later, and is implemented by using the SO_EXCLUSIVEADDRUSE option. WSA_QOS_SENDERS 11006 QoS senders. For more information describing how to back up the registry, refer to Microsoft Knowledge Base article 256986 Open the Windows Registry and navigate to this key: HKLM\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters Create a new DWORD http://isusaa.org/winsock-error/winsock-error-10048-ftp.php

How do I resolve the error " Winsock 10048 - Only one usage of each socket address"? For SilkPerformer one possible way to resolve this is to allow the agent machine(s) to open a greater number of TCP/IP ports. Can indicate a service provider implementation error. WSA_QOS_EFLOWDESC 11026 Invalid QoS flow descriptor.

Winsock Error 10048 Address Already In Use

Note that this error is returned by the operating system, so the error number may change in future releases of Windows. WSA_IO_PENDING 997 Overlapped operations will complete later. For example, this error is returned if sendto is called with the remote address of ADDR_ANY.

  • A required address was omitted from an operation on a socket.
  • No connection could be made because the target computer actively refused it.
  • Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind.
  • WSAECANCELLED 10103 Call has been canceled.
  • Applications that use WSAGetOverlappedResult (with the fWait flag set to FALSE) in a polling mode to determine when an overlapped operation has completed, get this error code until the operation is
  • An invalid or unrecognized service type was found in the QoS flowspec.
  • This documentation is archived and is not being maintained.
  • This error is returned by the WSCGetProviderInfo and WSCGetProviderInfo32 functions if the protocol entry specified could not be found.

However, it is interchangeable in most cases, and all Windows Sockets functions that return one of these messages also specify WSAEAFNOSUPPORT. How to write "Play this line, OR this line" with conventional music symbols Rank a list of integers more hot questions question feed lang-cpp about us tour help blog chat data This error is returned if either a service provider's DLL could not be loaded (LoadLibrary failed) or the provider's WSPStartup or NSPStartup function failed. Winsock Error Windows 7 WSAEPROTOTYPE 10041 Protocol wrong type for socket.

An invalid shape discard mode object was found in the QoS provider-specific buffer. Winsock Error 10048 3cdaemon An existing connection was forcibly closed by the remote host. Return code/valueDescription WSA_INVALID_HANDLE 6 Specified event object handle is invalid. http://community.microfocus.com/borland/test/silk_performer_-_application_performance_testing/w/knowledge_base/9672.how-do-i-resolve-the-error-winsock-10048-only-one-usage-of-each-socket-address.aspx A socket option is provided to allow faster reuse, setsockopt (SO_REUSEADDR).

A request to send or receive data was disallowed because the socket had already been shut down in that direction with a previous shutdown call. Winsock Error 10048 Windows 7 WSA_IO_INCOMPLETE 996 Overlapped I/O event object not in signaled state. A connect request was made on an already-connected socket. WSA_QOS_RECEIVERS 11005 QoS receivers.

Winsock Error 10048 3cdaemon

Old KB# 19445 Terms Of Use Privacy Statement Download Policy Microfocus.com Borland.com Support Line Corporate Blog Cookie Policy © 2001 - 2016 Micro Focus. hop over to this website If there is more than one Winsock DLL on your system, be sure the first one in the path is appropriate for the network subsystem currently loaded. Winsock Error 10048 Address Already In Use A socket operation failed because the destination host is down. Windows Socket Error 10048 On Api Bind WSAESOCKTNOSUPPORT 10044 Socket type not supported.

For server applications that need to bind multiple sockets to the same port number, consider using setsockopt (SO_REUSEADDR). his comment is here ANSWER ---------------------------------- The Windows Socket Error 10048 occurs when an application is unable to open a TCP/IP socket for communications with another application or computer. At least one QoS reserve has arrived. WSAVERNOTSUPPORTED 10092 Winsock.dll version out of range. Cannot Bind To Address Winsock Error 10048

In your case, you would add the following lines right after creating and checking ListenSocket: int optval = 1; iResult = ::setsockopt(ListenSocket, SOL_SOCKET, SO_REUSEADDR, &optval, sizeof optval); if (iResult == SOCKET_ERROR) Either the application has not called WSAStartup or WSAStartup failed. WSA_QOS_GENERIC_ERROR 11015 QoS generic error. this contact form Free PRTG Download >> What is this?

WSAEMFILE 10024 Too many open files. Winsock Error 10054 The application has initiated an overlapped operation that cannot be completed immediately. Operations that were in progress fail with WSAENETRESET.

An established connection was aborted by the software in your host computer, possibly due to a data transmission time-out or protocol error.

WSA_QOS_EOBJLENGTH 11022 Invalid QoS object length. The requested service provider is invalid. Another possible reason for the WSAEACCES error is that when the bind function is called (on Windows NT 4.0 with SP4 and later), another application, service, or kernel mode driver is bound to 10048 Error Sql Server What amount of samples to use?

WSAEINTR 10004 Interrupted function call. For information, see the Handling Winsock Errors topic. Normally, this indicates that the TCP/IP protocol is unavailable, or the desired port number for the socket is already in-use. navigate here An application used a Windows Sockets function that directly maps to a Windows function.

WSAEMSGSIZE 10040 Message too long. All Rights Reserved. | Affiliation of any organization with iYogi, Inc is not implied, unless expressly stated. asked 1 year ago viewed 1052 times active 1 year ago Related 0Different between none-blocking mode with async socket in C++ winsock server0WinSock2 bind error0Winsock select error 10038, bind and listen Missed appointment Are two standard normal random variables always independent?

This may be because the database files (for example, BSD-compatible HOSTS, SERVICES, or PROTOCOLS files) could not be found, or a DNS request was returned by the server with a severe At least one QoS send path has arrived. WSAELOOP 10062 Cannot translate name. An invalid QoS filter type was used.

The FormatMessage function can be used to obtain the message string for the returned error. First server is used' & 'Could not start session recording for server...' warnings returned at the start of a load test in Silk Performer when dynaTrace plugin is enabled 'Show TrueLog' Returned when a system call that should never fail does fail. WSA_QOS_ADMISSION_FAILURE 11010 QoS admission error.

Ran out of disk quota. Networking activity on the local host has not been initiated. The Windows function is indicating a problem with one or more parameters. Why increase the number of cylinders in an engine instead of increasing their volume?

The Windows Sockets implementation documentation to be sure all necessary components are currently installed and configured correctly. error networking registry webserver-stress-tool Created on Feb 24, 2010 9:05:50 AM by Daniel Zobel [Paessler Support] Last change on Jul 21, 2010 1:54:37 PM by Daniel Zobel [Paessler Support] Permalink 1 No such host is known. A QoS error occurred due to lack of resources.

This error occurs if an application passes an invalid pointer value, or if the length of the buffer is too small. This error occurs when your workstation cannot allocate new sockets.